Dr.Bhawesh chandra saha, Dr.Rashmi kumari, Dr.Bibhuti Prassan Sinha, Dr.NILESH MOHAN
Posterior capsular rupture during cataract surgery often go unidentified by the trainees and residents where further casual steps leads to catastrophic complications like dislocation of IOL into the vitreous cavity.Rarely one may notice one haptic of the IOL at the level of anterior vitreous when the haptic somehow entangles in between the fibres of iris or tags of anterior capsule.This viedeo demonstrates a case where a suspected dropped IOL gave a ray of hope when it was seen hanging inferiorly with one of its haptic stuck somewhere evident in downgaze of the patient.Visco was injected and a double angulated 30 G needle mounted on a tuberculin syringe was used to engage the haptic and gently take the IOL out without causing any turbulenec which at this stage could have have been lethal.There wasn’t any damage of the lens.Proper anterior vitrectomy was done and same IOL was implanted into the sulcus.Hence the once sinking IOL was rescued and secured with the help of a simple needle


Leave a Comment