Dr.Mahindrakar Aniruddha Dinkar, Dr.DHARMESH K KAR
Here we discuss how passing the suture with the reverse end through the wound helps in avoiding this tissue bite.
The straight needle is brought out through the main wound and then looped around the IOL haptic eye. When the suture (10-0 prolene) is passed back through the wound into the Anterior chamber it takes a tissue bite resulting in the suture passing through the corneal tissue instead of going out while suturing the scleral fixated IOL. By passing the suture with the reverse end through the wound into the 26 g needle helps in avoiding this tissue bite. This makes the procedure less complicated.