Dr.Sanjay Chaudhary, Dr.Rahil Chaudhary, Dr.SARIKA JINDAL
The vertical dimension of the natural lens was about 10 mm while the horizontal dimension was 6 mm. A 3.75 mm rhexis is made with needle and forceps. After hydrodissection, CTR is placed in bag. Anterior Chamber maintainer (ACM) is placed through scleral side of limbus so as not to cause corneal wrinkles, and is attached to a bottle at a height of 30 cm. Capsular hooks hold the bag during cortex removal. Ahmed Segment centralises the bag further, and secures it to the sclera through a Hoffmann’s pouch. IOL is place in bag and lies well centred
Results: CTR expands the 6 mm lens to 7.5 mm. Ahmed segments pull, further expands the bag to 8.5 mm and centralises it with a little stretch of the elastic zonules of the opposite side. The maximum Intraocular Pressure is 30mmhg using Active Fluidics, while the minimum is 21 mmhg using the ACM attached to bottle at a height of 30 cm. This keeps the chamber stable and vitreous at bay even while moving instruments in and out of the eye.


Leave a Comment